GREYSTONE HOME PRODUCTS LLC ABFRBR414 FLOOR REGISTER BROWN 4″ X 14″

January 30, 2010 by  
Filed under Floor Vents

GREYSTONE HOME PRODUCTS LLC ABFRBR414 FLOOR REGISTER BROWN 4

GREYSTONE FLOOR REGISTER Heavy steel construction Smooth operating multi- shutter damper Durable powder coated brown finish 4″ x 14″

(more…)

Alcoa Home Exteriors OCTGV18 A7 Octagon Gable Vent

January 30, 2010 by  
Filed under Gable Wall Vents

Alcoa Home Exteriors OCTGV18 A7 Octagon Gable Vent

18″ x 18″ 2 piece. Base is fully compatible with all siding profiles. Install the base with the siding and snap on the cover later. Ventilated opening: 10″ x 12 1 2″. Outside unit dimensions: 18″. Net free area: 50.7 sq. in. Siding receiver 5 8″ to 1 1 4″

(more…)

Alcoa Home Exteriors OCTGV18 EQ Octagon Gable Vent

January 27, 2010 by  
Filed under Gable Wall Vents

Alcoa Home Exteriors OCTGV18 EQ Octagon Gable Vent

18″ x 18″ 2 piece. Base is fully compatible with all siding profiles. Install the base with the siding and snap on the cover later. Ventilated opening: 10″ x 12 1 2″. Outside unit dimensions: 18″. Net free area: 50.7 sq. in. Siding receiver 5 8″ to 1 1 4″

(more…)

Greystone Home Products Llc ABSWWH3146 3-way Wall/ceiling Register 14″x6″ – White

January 24, 2010 by  
Filed under Wall Vents

Greystone Home Products Llc ABSWWH3146 3-way Wall/ceiling Register 14

GREYSTONE” 3-WAY WALL/ CEILING REGISTER 14″ x 6″ Heavy steel construction Smooth operating compact damper switch For sidewall or ceiling applications 1/2″ spaced fins Durable powder coated white finish Listed size is duct size unit fits New register that compliments the rest of the line.

(more…)

Alcoa Home Exteriors SQGV1414 PA Square Gable Vent

January 21, 2010 by  
Filed under Gable Wall Vents

Alcoa Home Exteriors SQGV1414 PA Square Gable Vent

2 piece. Base is fully compatible with all siding profiles. Install the base with the siding and snap on the cover later. Square 14″ x 14″: Ventilated opening 10″ x 12 1 2″; outside unit dimensions 14″ x 14″; net free area 33.7 sq. in. No. SQGV1414 04: Wh

(more…)

How to ventilate the attic in a home

January 19, 2010 by  
Filed under Attic Vents, Gable Wall Vents

Attic ventilation is done to cool the insulated ceiling space in a home. The vents allow air to enter into the space between the ceiling and the roof. This space sometimes has damp air or due to hot weather it gets quite stuffy. The insulation applied in the ceiling space in the attic sometimes produces vapor. The cool air in the from the vents assists in removing this mist air. The vents are done on two opposite walls in the roof space for cross ventilation to take place.

Attic ventilation is done on the gable walls opposite each other. This are the triangular walls in the home after the ring beam. The size of the vent space is about two feet by two and a half feet wide. They are usually timber louvers fixed in a frame work. They should allow air passage into the roof space without letting in rain water. The louvers should also be provided with a shutter to close. This is in particular weather with very low temperatures like winter or severe storms.

The attic ventilation commences by marking the position on the wall. This is done for old houses while for a new wall the space is marked an left open. The wall is cut at two courses from the gable top. The wall is then plastered to the required finish after roofing. The frame work is done of two feet wide by two and a half high. This frame w work is done with treated and dry timber. This is because of the position at which it is fixed. It should take harsh weather conditions without getting damaged.

The frame work is then positioned at two inches into the wall. The timber members are four by two inches thick. Fixing is by screwing into the wall. The upright members have slots angled at forty five degrees. The louvers are timber pieces of two by a three quarter inch thick. They are then inserted and glued into the angled slots. Painting is done with oil paint. A gauze wire is then nailed on the inside of the wall to prevent birds and pests from coming into the attic room.

Andrew Karundu Is A Building Economist, Providing Home Based Solutions To Fixing, Repairing, Remodeling And Redesigning Homes. He Uses Simple Tried And Tested Methods To Improve Family Lifestyles.Visit His Site Here For Adequate Information On Most HOME IMPROVEMENT SOLUTIONS.

Alcoa Home Exteriors OCTGV18 BI Octagon Gable Vent

January 18, 2010 by  
Filed under Gable Wall Vents

Alcoa Home Exteriors OCTGV18 BI Octagon Gable Vent

18″ x 18″ 2 piece. Base is fully compatible with all siding profiles. Install the base with the siding and snap on the cover later. Ventilated opening: 10″ x 12 1 2″. Outside unit dimensions: 18″. Net free area: 50.7 sq. in. Siding receiver 5 8″ to 1 1 4″

(more…)

Alcoa Home Exteriors SQGV1414 PP Square Gable Vent

January 15, 2010 by  
Filed under Gable Wall Vents

Alcoa Home Exteriors SQGV1414 PP Square Gable Vent

2 piece. Base is fully compatible with all siding profiles. Install the base with the siding and snap on the cover later. Square 14″ x 14″: Ventilated opening 10″ x 12 1 2″; outside unit dimensions 14″ x 14″; net free area 33.7 sq. in. No. SQGV1414 04: Wh

(more…)

GREYSTONE HOME PRODUCTS LLC ABFRWH412 FLOOR DIFFUSER WHITE 12” x 4”

January 15, 2010 by  
Filed under Floor Vents

GREYSTONE HOME PRODUCTS LLC ABFRWH412 FLOOR DIFFUSER WHITE 12'' x 4''

GREYSTONE FLOOR REGISTER Heavy steel construction Smooth operating multi-shutter damper Durable powder coated white finish Listed size is duct size unit fits 4″ x 12″

(more…)

Alcoa Home Exteriors SQGV1414 A7 Square Gable Vent

January 12, 2010 by  
Filed under Gable Wall Vents

Alcoa Home Exteriors SQGV1414 A7 Square Gable Vent

2 piece. Base is fully compatible with all siding profiles. Install the base with the siding and snap on the cover later. Square 14″ x 14″: Ventilated opening 10″ x 12 1 2″; outside unit dimensions 14″ x 14″; net free area 33.7 sq. in. No. SQGV1414 04: Wh

(more…)

Next Page »